PropertySetTemplates for: IfcSpace

Pset_EnvironmentalImpactIndicators

Environmental impact indicators are related to a given \X2\201C\X0\functional unit\X2\201D\X0\ (ISO 14040 concept). An example of functional unit is a "Double glazing window with PVC frame" and the unit to consider is "one square meter of opening elements filled by this product\X2\201D\X0\.\X\0AIndicators values are valid for the whole life cycle or only a specific phase (see LifeCyclePhase property). Values of all the indicators are expressed per year according to the expected service life. The first five properties capture the characteristics of the functional unit. The following properties are related to environmental indicators.\X\0AThere is a consensus agreement international for the five one. Last ones are not yet fully and formally agreed at the international level.

ApplicableEntities:IfcElement

NamePrimaryMeasureType
AtmosphericAcidificationPerUnitIfcMassMeasure
ClimateChangePerUnitIfcMassMeasure
EutrophicationPerUnitIfcMassMeasure
ExpectedServiceLifeIfcTimeMeasure
FunctionalUnitReferenceIfcLabel
HazardousWastePerUnitIfcMassMeasure
InertWastePerUnitIfcMassMeasure
LifeCyclePhaseIfcLabel
NonHazardousWastePerUnitIfcMassMeasure
NonRenewableEnergyConsumptionPerUnitIfcEnergyMeasure
PhotochemicalOzoneFormationPerUnitIfcMassMeasure
RadioactiveWastePerUnitIfcMassMeasure
ReferenceIfcIdentifier
RenewableEnergyConsumptionPerUnitIfcEnergyMeasure
ResourceDepletionPerUnitIfcMassMeasure
StratosphericOzoneLayerDestructionPerUnitIfcMassMeasure
TotalPrimaryEnergyConsumptionPerUnitIfcEnergyMeasure
UnitIfcText
WaterConsumptionPerUnitIfcVolumeMeasure


Pset_EnvironmentalImpactValues

The following properties capture environmental impact values of an element. They correspond to the indicators defined into Pset_EnvironmentalImpactIndicators. \X\0AEnvironmental impact values are obtained multiplying indicator value per unit by the relevant quantity of the element.

ApplicableEntities:IfcElement

NamePrimaryMeasureType
AtmosphericAcidificationIfcMassMeasure
ClimateChangeIfcMassMeasure
EutrophicationIfcMassMeasure
HazardousWasteIfcMassMeasure
InertWasteIfcMassMeasure
NonHazardousWasteIfcMassMeasure
NonRenewableEnergyConsumptionIfcEnergyMeasure
PhotochemicalOzoneFormationIfcMassMeasure
RadioactiveWasteIfcMassMeasure
RenewableEnergyConsumptionIfcEnergyMeasure
ResourceDepletionIfcMassMeasure
StratosphericOzoneLayerDestructionIfcMassMeasure
TotalPrimaryEnergyConsumptionIfcEnergyMeasure
WaterConsumptionIfcVolumeMeasure


Pset_SpaceCommon

Properties common to the definition of all occurrences of IfcSpace. Please note that several space attributes are handled directly at the IfcSpace instance, the space number (or short name) by IfcSpace.Name, the space name (or long name) by IfcSpace:LongName, and the description (or comments) by IfcSpace.Description. Actual space quantities, like space perimeter, space area and space volume are provided by IfcElementQuantity, and space classification according to national building code by IfcClassificationReference. The level above zero (relative to the building) for the slab row construction is provided by the IfcBuildingStorey.Elevation, the level above zero (relative to the building) for the floor finish is provided by the IfcSpace.ElevationWithFlooring.

ApplicableEntities:IfcSpace

NamePrimaryMeasureType
GrossPlannedAreaIfcAreaMeasure
HandicapAccessible e.g.
IsExternal.P_SINGLEVALUE.
NetPlannedAreaIfcAreaMeasure
PubliclyAccessible e.g.
Reference.P_SINGLEVALUE.


Pset_SpaceCoveringRequirements

Properties common to the definition of covering requirements of IfcSpace. Those properties define the requirements coming from a space program in early project phases and can later be used to define the room book information, if such coverings are not modeled explicitly as covering elements.

ApplicableEntities:IfcSpace

NamePrimaryMeasureType
CeilingCovering.P_SINGLEVALUE.
CeilingCoveringThickness the geometric parameters take precedence.
ConcealedCeiling.P_SINGLEVALUE.
ConcealedFlooring.P_SINGLEVALUE.
FloorCovering.P_SINGLEVALUE.
FloorCoveringThickness the geometric parameters take precedence.
Molding.P_SINGLEVALUE.
MoldingHeight.P_SINGLEVALUE.
SkirtingBoard.P_SINGLEVALUE.
SkirtingBoardHeight.P_SINGLEVALUE.
WallCovering.P_SINGLEVALUE.
WallCoveringThickness the geometric parameters take precedence.


Pset_SpaceFireSafetyRequirements

Properties related to fire protection of spaces that apply to the occurrences of IfcSpace or IfcZone.

ApplicableEntities:IfcSpace, IfcSpatialZone, IfcZone

NamePrimaryMeasureType
AirPressurization.P_SINGLEVALUE.
FireExit e.g.
FireRiskFactorIfcLabel
FlammableStorage (FALSE)
SprinklerProtection.P_SINGLEVALUE.
SprinklerProtectionAutomatic if the property "SprinklerProtection" is set to TRUE.


Pset_SpaceLightingRequirements

Properties related to the lighting requirements that apply to the occurrences of IfcSpace or IfcZone. This includes the required artificial lighting, illuminance, etc.

ApplicableEntities:IfcSpace, IfcSpatialZone, IfcZone

NamePrimaryMeasureType
ArtificialLighting.P_SINGLEVALUE.
IlluminanceIfcIlluminanceMeasure


Pset_SpaceOccupancyRequirements

Properties concerning work activities occurring or expected to occur within one or a set of similar spatial structure elements.

ApplicableEntities:IfcSpace, IfcSpatialZone, IfcZone

NamePrimaryMeasureType
AreaPerOccupantIfcAreaMeasure
IsOutlookDesirable.P_SINGLEVALUE.
MinimumHeadroomIfcLengthMeasure
OccupancyNumberIfcCountMeasure
OccupancyNumberPeakIfcCountMeasure
OccupancyTimePerDayIfcTimeMeasure
OccupancyTypeIfcLabel


Pset_SpaceParking

Properties common to the definition of all occurrences of IfcSpace which have an attribute value for ObjectType = ''Parking''.

Note: Modified in IFC 2x3, properties ParkingUse and ParkingUnits added.

ApplicableEntities:IfcSpace/PARKING

NamePrimaryMeasureType
IsAisle
IsOneWay.P_SINGLEVALUE.
ParkingUnits where the parking space is for motorcycles or bicycles
ParkingUse motorcycle


Pset_SpaceThermalRequirements

Properties related to the comfort requirements for thermal and other thermal related performance properties of spaces that apply to the occurrences of IfcSpace, IfcSpatialZone or IfcZone. It can also be used to capture requirements for IfcSpaceType''s. This includes the required design temperature, humidity, ventilation, and air conditioning.

ApplicableEntities:IfcSpace, IfcSpatialZone, IfcZone

NamePrimaryMeasureType
AirConditioning.P_SINGLEVALUE.
AirConditioningCentral if the property "AirConditioning" is set to TRUE.
DiscontinuedHeating (FALSE)
MechanicalVentilationRate.P_SINGLEVALUE.
NaturalVentilation.P_SINGLEVALUE.
NaturalVentilationRate.P_SINGLEVALUE.
SpaceHumidity otherwise for the intermediate period. Provide this property
SpaceHumidityMax otherwise for the intermediate period.
SpaceHumidityMin otherwise for the intermediate period.
SpaceHumiditySummer that is required from user/designer view point and provided as requirement for cooling.
SpaceHumidityWinter.P_SINGLEVALUE.
SpaceTemperature it applies all year
SpaceTemperatureMax it applies all year
SpaceTemperatureMin it applies all year
SpaceTemperatureSummerMax that is required from user/designer view point and provided as requirement for cooling.
SpaceTemperatureSummerMin that is required from user/designer view point and provided as requirement for cooling.
SpaceTemperatureWinterMax that is required from user/designer view point and provided as requirement for heating.
SpaceTemperatureWinterMin that is required from user/designer view point and provided as requirement for heating.


Pset_SpaceThermalPHistory

Thermal and air flow conditions of a space or zone. HISTORY: New property set in IFC 2x2.

ApplicableEntities:IfcSpace

NamePrimaryMeasureType
CoolingAirFlowRateIfcTimeSeries
ExhaustAirFlowRateIfcTimeSeries
HeatingAirFlowRateIfcTimeSeries
SpaceRelativeHumidityIfcTimeSeries
SpaceTemperatureIfcTimeSeries
VentilationAirFlowRateIfcTimeSeries


Pset_SpaceThermalLoadPHistory

The space thermal load IfcSpaceThermalLoadProperties defines actual measured thermal losses and gains occurring within a space or zone. The thermal load source attribute defines an enumeration of possible sources of the thermal load.

ApplicableEntities:IfcSpace

NamePrimaryMeasureType
AirExchangeRateIfcTimeSeries
DryBulbTemperatureIfcTimeSeries
EquipmentSensibleIfcTimeSeries
ExhaustAirIfcTimeSeries
InfiltrationSensibleIfcTimeSeries
LightingIfcTimeSeries
PeopleIfcTimeSeries
RecirculatedAirIfcTimeSeries
RelativeHumidityIfcTimeSeries
TotalLatentLoad then the thermal load is a gain to the space.
TotalRadiantLoad then the thermal load is a gain to the space.
TotalSensibleLoad then the thermal load is a gain to the space.
VentilationIndoorAirIfcTimeSeries
VentilationOutdoorAirIfcTimeSeries


Pset_SpaceHeaterPHistory

Space heater performance history common attributes.

ApplicableEntities:IfcSpaceHeater

NamePrimaryMeasureType
AirResistanceCurve
AuxiliaryEnergySourceConsumptionIfcTimeSeries
EffectivenessIfcTimeSeries
Exponent.
FractionConvectiveHeatTransferIfcTimeSeries
FractionRadiantHeatTransferIfcTimeSeries
HeatOutputRateIfcTimeSeries
OutputCapacityCurve
SpaceAirTemperatureIfcTimeSeries
SpaceMeanRadiantTemperatureIfcTimeSeries
SurfaceTemperatureIfcTimeSeries
UACurve.P_REFERENCEVALUE.


Pset_ManufacturerTypeInformation

Defines characteristics of types (ranges) of manufactured products that may be given by the manufacturer. Note that the term ''manufactured'' may also be used to refer to products that are supplied and identified by the supplier or that are assembled off site by a third party provider. \X\0AHISTORY: This property set replaces the entity IfcManufacturerInformation from previous IFC releases. IFC 2x4: AssemblyPlace property added.

ApplicableEntities:IfcElement

NamePrimaryMeasureType
ArticleNumberIfcIdentifier
AssemblyPlace.P_ENUMERATEDVALUE.
GlobalTradeItemNumber.P_SINGLEVALUE.
ManufacturerIfcLabel
ModelLabel.P_SINGLEVALUE.
ModelReference.P_SINGLEVALUE.
ProductionYearIfcLabel


Pset_ManufacturerOccurrence

Defines properties of individual instances of manufactured products that may be given by the manufacturer.\X\0AHISTORY: IFC 2x4: AssemblyPlace property added. This property does not need to be asserted if Pset_ManufacturerTypeInformation is allocated to the type and the AssemblyPlace property is asserted there.

ApplicableEntities:IfcElement

NamePrimaryMeasureType
AcquisitionDateIfcDate
AssemblyPlace other offsite location or on the building site.
BarCodeIfcIdentifier
BatchReferenceIfcIdentifier
SerialNumberIfcIdentifier


Qto_SpaceBaseQuantities

Base quantities that are common to the definition of all occurrences of spaces.

ApplicableEntities:IfcSpace

NamePrimaryMeasureType
FinishCeilingHeight.Q_LENGTH.
FinishFloorHeight.Q_LENGTH.
GrossCeilingArea.
GrossFloorArea.Q_AREA.
GrossPerimeter.
GrossVolume.Q_VOLUME.
GrossWallArea.
Height.Q_LENGTH.
NetCeilingArea.
NetFloorArea or other protruding elements. Varying heights are not taking into account (i.e. no reduction for areas under a minimum headroom)
NetPerimeter.Q_LENGTH.
NetVolume.Q_VOLUME.
NetWallArea.


Pset_SpaceHeaterTypeRadiator

Space heater type radiator attributes.

ApplicableEntities:IfcSpaceHeater/RADIATOR

NamePrimaryMeasureType
RadiatorTypeIfcLabel
TubingLengthIfcPositiveLengthMeasure
WaterContentIfcMassMeasure


Pset_SoundGeneration

Common definition to capture the properties of sound typically used within the context of building services and flow distribution systems. This property set is instantiated multiple times on an object for each frequency band. HISTORY: New property set in IFC Release 2x4.

ApplicableEntities:IfcDistributionFlowElement

NamePrimaryMeasureType
SoundCurve.P_TABLEVALUE.


Pset_PropertyAgreement

A property agreement is an agreement that enables the occupation of a property for a period of time.
The objective is to capture the information within an agreement that is relevant to a facilities manager. Design and construction information associated with the property is not considered. A property agreement may be applied to an instance of IfcSpatialStructureElement including to compositions defined through the IfcSpatialStructureElement.Element.CompositionEnum.
Note that the associated actors are captured by the IfcOccupant class.

ApplicableEntities:IfcSpatialStructureElement

NamePrimaryMeasureType
AgreementTypeIfcLabel
CommencementDateIfcDate
ConditionCommencement broom clean
ConditionTermination broom clean
DurationIfcDuration
IdentifierIfcIdentifier
OptionsIfcText
PropertyNameIfcLabel
RestrictionsIfcText
TerminationDateIfcDate
VersionIfcLabel
VersionDateIfcDate


Pset_SpaceThermalLoad

The space thermal load defines all thermal losses and gains occurring within a space or zone. The thermal load source attribute defines an enumeration of possible sources of the thermal load. The maximum, minimum, time series and app

ApplicableEntities:IfcSpace

NamePrimaryMeasureType
AirExchangeRateIfcPowerMeasure
DryBulbTemperatureIfcPowerMeasure
EquipmentSensibleIfcPowerMeasure
ExhaustAirIfcPowerMeasure
InfiltrationSensibleIfcPowerMeasure
LightingIfcPowerMeasure
PeopleIfcPowerMeasure
RecirculatedAirIfcPowerMeasure
RelativeHumidityIfcPowerMeasure
TotalLatentLoad then the thermal load is a gain to the space.
TotalRadiantLoad then the thermal load is a gain to the space.
TotalSensibleLoad then the thermal load is a gain to the space.
VentilationIndoorAirIfcPowerMeasure
VentilationOutdoorAirIfcPowerMeasure


Pset_SpaceHeaterTypeCommon

Space heater type common attributes.\X\0ASoundLevel attribute deleted in IFC2x2 Pset Addendum: Use IfcSoundProperties instead. Properties added in IFC2x4.

ApplicableEntities:IfcSpaceHeater

NamePrimaryMeasureType
BodyMassIfcMassMeasure
EnergySourceIfcLabel
HeatTransferDimensionIfcLabel
HeatTransferMediumIfcLabel
NumberOfPanelsIfcInteger
NumberOfSections.P_SINGLEVALUE.
OutputCapacityIfcPowerMeasure
PlacementTypeIfcLabel
Reference.P_SINGLEVALUE.
Status "Existing" - element exists and remains
TemperatureClassification usually heated by gas or steam.
ThermalEfficiencyIfcNormalisedRatioMeasure
ThermalMassHeatCapacityIfcReal


Pset_ServiceLife

Captures the period of time that an artifact will last along with various factors that impact the expected service life. HISTORY: Introduced in IFC2X4 as replacement for IfcServiceLife and IfcServiceLifeFactor.

ApplicableEntities:IfcElement

NamePrimaryMeasureType
DesignLevelIfcPositiveRatioMeasure
InUseConditionsIfcPositiveRatioMeasure
IndoorEnvironment.P_BOUNDEDVALUE.
MaintenanceLevelIfcPositiveRatioMeasure
MeanTimeBetweenFailureIfcDuration
OutdoorEnvironment.P_BOUNDEDVALUE.
QualityOfComponentsIfcPositiveRatioMeasure
ServiceLifeDurationIfcDuration
ServiceLifeTypeIfcLabel
WorkExecutionLevelIfcPositiveRatioMeasure


Pset_Warranty

An assurance given by the seller or provider of an artefact that the artefact is without defects and will operate as described for a defined period of time without failure and that if a defect does arise during that time, that it will be corrected by the seller or provider.

ApplicableEntities:IfcElement

NamePrimaryMeasureType
Exclusions.P_SINGLEVALUE.
IsExtendedWarranty.P_SINGLEVALUE.
PointOfContact.P_REFERENCEVALUE.
WarrantyContentIfcText
WarrantyEndDateIfcDate
WarrantyIdentifierIfcIdentifier
WarrantyPeriodIfcTimeMeasure
WarrantyStartDateIfcDate


Pset_SpaceHeaterTypeConvector

Space heater type convector attributes.

ApplicableEntities:IfcSpaceHeater/CONVECTOR

NamePrimaryMeasureType
ConvectorType.


Pset_Condition

Determines the state or condition of an element at a particular point in time.

ApplicableEntities:IfcElement

NamePrimaryMeasureType
AssessmentCondition OK
AssessmentDateIfcDate
AssessmentDescriptionIfcText


Qto_SpaceHeaterBaseQuantities

Base quantities that are common to the definition of all types of space heaters.

ApplicableEntities:IfcSpaceHeater

NamePrimaryMeasureType
GrossWeight.Q_WEIGHT.
Length.Q_LENGTH.
NetWeight.Q_WEIGHT.


Pset_ElectricalDeviceTypeCommon

A collection of properties that are commonly used by electrical device types.

ApplicableEntities:IfcDistributionElement

NamePrimaryMeasureType
ConductorFunction. Protective Earth is sometimes also known as CPC or common protective conductor. Note that for an electrical device
HasProtectiveEarth.P_SINGLEVALUE.
IP_Code.P_SINGLEVALUE.
InsulationStandardClass as well as other factors. Also indicates whether the electrical device has a protective earth connection.
NominalFrequencyRangeIfcFrequencyMeasure
NumberOfPolesIfcInteger
PowerFactorIfcNormalisedRatioMeasure
RatedCurrentIfcElectricCurrentMeasure
RatedVoltageIfcElectricVoltageMeasure


Pset_AirSideSystemInformation

Attributes that apply to an air side HVAC system. HISTORY: New property set in IFC Release 1.0.

ApplicableEntities:IfcSpace,IfcZone,IfcSpatialZone

NamePrimaryMeasureType
AirSideSystemDistributionType.P_ENUMERATEDVALUE.
AirSideSystemType.P_ENUMERATEDVALUE.
AirflowSensibleIfcVolumetricFlowRateMeasure
ApplianceDiversityIfcPositiveRatioMeasure
CoolingTemperatureDeltaIfcThermodynamicTemperatureMeasure
DescriptionIfcLabel
EnergyGainSensible.P_SINGLEVALUE.
EnergyGainTotal.P_SINGLEVALUE.
EnergyLossIfcPowerMeasure
FanPowerIfcPowerMeasure
HeatingTemperatureDeltaIfcThermodynamicTemperatureMeasure
InfiltrationDiversitySummerIfcPositiveRatioMeasure
InfiltrationDiversityWinterIfcPositiveRatioMeasure
LightingDiversityIfcPositiveRatioMeasure
LoadSafetyFactorIfcPositiveRatioMeasure
NameIfcLabel
TotalAirflow.P_SINGLEVALUE.
VentilationIfcVolumetricFlowRateMeasure